Lub tshuab hluav taws xob Rectifier yog cov cuab yeej tseem ceeb sib txuas rau lub hwj chim rau ACC / DC cov lej uas yuav tsum tau ua rau ACCEs, thiab kev tswj hwm DC. Nws yog dav siv nyob rau hauv cov liaj teb xws li electrolysis, Aluminium smelting, thiab graphitization. Vim tias tsis tshua muaj siab-sab uas muaj cov hloov pauv, cov hluav taws xob hloov hluav taws xob feem ntau tuaj nrog cov khoom siv sib tua tseem ceeb tshwm sim los ntawm cov khoom siv hluav taws xob.
daim duab
Cov khoom lag luam parameter
|
Kev Muaj Peev Xwm(KVA) |
Rated Muaj Peev Xwm Thauj Khoom Poob (W) |
Tsis muaj-thauj khoom tam sim no (%) |
Impedance voltage (%) |
|
30 |
600 |
2.1 |
6 |
|
125 |
1800 |
1.5 |
5 |
|
250 |
3050 |
1.2 |
4 |
|
250 |
3050 |
1.2 |
7 |
|
315 |
3650 |
1.1 |
4 |
|
400 |
4300 |
1 |
6 |
|
420 |
4500 |
1 |
10 |
|
436 |
4500 |
1 |
8 |
|
460 |
5000 |
1 |
4 |
|
475 |
5000 |
1 |
7.5 |
|
500 |
5100 |
1 |
8 |
|
560 |
5700 |
0.9 |
4.27 |
|
593 |
6000 |
0.9 |
4.5 |
|
600 |
6000 |
0.9 |
6.3 |
|
630 |
6200 |
0.8 |
6 |
|
800 |
7500 |
0.8 |
7.2 |
|
2×400 |
7500 |
0.8 |
4 |
|
900 |
9200 |
0.7 |
6.3 |
|
1000 |
10300 |
0.6 |
6 |
|
1228 |
12000 |
0.6 |
6 |
|
1250 |
12000 |
0.6 |
6 |
|
1400 |
13300 |
0.6 |
6 |
|
1500 |
14000 |
0.6 |
0.75 |
|
1600 |
14500 |
0.6 |
6 |
|
1800 |
16000 |
0.9 |
6 |
|
2000 |
17800 |
0.9 |
7.2 |
|
2400 |
20700 |
0.8 |
8 |
|
2500 |
20700 |
0.8 |
7.5 |
|
2×1300 |
20700 |
0.8 |
4 |
|
2800 |
23000 |
0.8 |
12 |
|
2×1450 |
23000 |
0.8 |
4 |
|
3000 |
23000 |
0.8 |
7.85 |
|
3150 |
24300 |
0.8 |
6.5 |
|
3200 |
24300 |
0.8 |
8 |
1000Kva Rectifier Transformer Khoom Piav qhia
Lub ntsiab ntawm Rectifier hloov pauv yog raws li hauv qab no:
Ib Leeg-Phaj Rectifier Transformer: Haum rau cov khoom siv hluav taws xob tsawg.
Peb-theem Rectifier Transformer: Siv dav hauv cov teb muaj hluav taws xob thiab cov electrolilating, muab cov zis ruaj khov.
Tus autotransformer Rectifier: Paffes txuag hluav taws xob hloov kho los ntawm kev tswj hwm hluav taws xob thiab feem ntau siv nyob rau hauv cov xwm txheej tshwj xeeb los txo kev poob.
Theem-hloov Rectifier Transformer: Siv hauv ntau lub tshuab tswj cov mem tes ntau MSALSE, txo cov ntsiab lus harmonic thiab txhim kho cov zog zoo.
Hauv kev siv cov ntawv thov, cov hauv qab no yuav tsum tau sau tseg thaum siv Rectifier hloov pauv:
Kev harmonic sawb: Vim tias cov khoom pauv hluav taws xob tsim cov kev sib raug zoo, cov khoom siv lim yuav tsum tau muab tso rau kom muaj kuab paug thiab kom muaj zog.
Kev Tswj Cov Thermal: Rectifier hloov pauv feem ntau ua haujlwm hauv qab cov kev tsim kho siab, yog li cov cua sov tsis txaus thiab ua pa yog qhov tseem ceeb rau kev ua haujlwm ruaj khov.
Rwb thaiv tsev kev ua haujlwm: Vim tias siab ua hauj lwm voltages, qhov zoo tshaj ntawm transformer cov ntaub ntawv rwb thaiv tsev yuav tsum muaj kev ntseeg siab kom tiv thaiv kev rhuav tshem.
Load Matching: Transformer muaj peev xwm yuav tsum raug xaiv kom tsis txhob muaj kev ua haujlwm dhau lossis lub teeb ua haujlwm zoo, uas hloov kho kev ua haujlwm zoo.
Thib Ob Txoj Kev Txwv Tam Sim No: Rau cov ntawv thov nrog cov khoom siv siab zuj zus los xij yuav tsum tau nruab los tiv thaiv luv luv lossis ntau dhau los ua khoom siv.
SGS Daim Ntawv Pov Thawj Ntawv Pov Thawj

Txog Peb





Cov FAQ
Cim npe nrov: 1000KVA Rectifier Transformer, Tuam Tshoj 1000Kva Rectifier Transformer tuam ntxhab, lwm tus neeg, Hoobkas
Xa kev nug