2 × 1450 KVA Roj Immersed Rectifier Transformer
Hauj lwm lawm
Kev tsis
Henan GNEE Electric Co., Ltd. yog ib qho ntawm cov ua lag luam thiab cov neeg muag khoom ntawm 2 × 1450 kva roj immersed rectifier transformer hauv Suav teb, kuj txhawb kev pabcuam customized nrog tus nqi qis. Txais tos kom yuav luv nqi 2 × 1450 kva roj immersed rectifier transformer rau muag ntawm no los ntawm peb lub hoobkas. Yog tias koj muaj lus nug txog pricelist, thov koj xav email rau peb.
roj - immersed rectifier transformer qhia
Cov roj - immersed rectifier transformer yog ib qho tseem ceeb ntawm lub zog hloov khoom siv. Immersed nyob rau hauv insulating roj, nws ua kom muaj cua sov dissipation thiab txhim khu kev qha rwb thaiv tsev. Nrog rau tag nrho lub peev xwm ntawm 2 × 1450 KVA, nws tuaj yeem ua haujlwm loj - nplai fais fab kev kho kom zoo. Hom roj no immersed traction rectifier transformer converts alternating tam sim no rau hauv ncaj qha tam sim no, dav siv nyob rau hauv kev lag luam xws li electroplating, roj teeb them, thiab hluav taws xob traction, muab ruaj khov thiab muaj zog DC zog.
Roj immersed traction rectifier transformer Video
2 × 1450 KVA roj immersed rectifier transformer nthuav dav
Advanced Fully Sealed Oil-Immersed Power Transformer los ntawm GNEE
GNEE cov roj ntim tag nrho-immersed power transformer sawv cev rau lub zog ntawm lub zog- tsim kom muaj txiaj ntsig zoo, tsim kom muaj kev poob qis, suab nrov tsawg, thiab kev ua haujlwm zoo dua. Qhov kev daws teeb meem tshiab no tsis yog tsuas yog txo qis kev siv hluav taws xob xwb tab sis kuj txo qis kev cuam tshuam ib puag ncig, ua rau nws yog qhov kev xaiv zoo tshaj plaws rau kev faib hluav taws xob ruaj khov.
Nyob rau hauv lub hauv paus ntawm no transformer tus tsim yog nws revolutionary corrugated tank qauv. Tsis zoo li cov roj ib txwm siv- cov qauv raus dej, GNEE's transformer tshem tawm qhov xav tau ntawm cov roj txuag. Es tsis txhob, lub corrugated tank lub inherent elasticity enables tsis siv neeg hloov ntawm cov roj ntim, zoo cais lub transformer los ntawm huab cua raug. Qhov kev tsim qauv no tiv thaiv cov roj oxidation thiab rwb thaiv tsev degradation, ua kom cov transformer muaj kev ntseeg siab ua haujlwm thaum txo cov kev xav tau ntawm kev saib xyuas. Nrog GNEE cov kev txawj ntse, cov neeg siv khoom tuaj yeem cia siab tias yuav muaj kev ruaj khov, siab -kev ua haujlwm zoo uas ua kom zoo dua - lub sijhawm ua haujlwm tau zoo thiab txuag nqi.
Khoom Qhia

Peb Cov Khoom Muag
Lub Zog Muaj Peev Xwm: 25 - 3200 KVA
Qib Voltage: 10 KV, 11 KV, 13.8 KV, 15 KV, 17.5 KV, 20 KV, 22 KV, 24 KV, 30 KV, 33 KV, 35 KV, 36 KV ... 132 KV, thiab lwm yam raws li tus neeg yuav tsum tau muaj
Hom Kev Tswj Hluav Taws Xob: Tawm - Circuit Court lossis On - load
Tapping ntau yam: ± 5%, ± 2 × 2.5%, ± 4 × 2.5%
Zaus: 50 Hz lossis 60 Hz
Theem: Peb - theem lossis ib zaug - theem
Cov cim kev sib txuas: Dyn11, Yyn0 (los yog raws li xav tau)
Luv - Circuit Court impedance: Standard impedance
Qhov siab: tsis tshaj 1000 m
Ambient Kub: tsis tshaj 40 degree
Yog tias tsis tuaj yeem ua raws li cov xwm txheej saum toj no, peb yuav kho qhov tsis ua raws li cov qauv tsim nyog.
Technical data sheet
| Main Technical Parameter (tuaj yeem kho nws raws li koj cov ntaub ntawv thev naus laus zis) | ||||||||||
| Rated | Voltage kev sib xyaw | Vector | Tsis muaj -load | Load Loss | Tsis muaj -load | Luv -circuitimpedance | Qhov hnyav (kG) | |||
| Peev xwm (KVA) | High Voltage (KA) | High Voltage | Tsawg Voltage (KA) | Pab pawg | Lossis (KW) | (KW) | Tam sim no% | Roj Qhov hnyav | Qhov hnyav tag nrho | |
| Tapping Range | ||||||||||
| 30 | 20 -10 | ±5×2.5% ±2×2.5% |
0.4 | Dyn 11 | 0.09 | 0.66 | 2.1 | 5.5 | 180 | 420 |
| 50 | 0.13 | 0.96 | 2 | 150 | 495 | |||||
| 63 | 0.15 | 1.145 | 1.9 | 170 | 560 | |||||
| 80 | 0.18 | 1.37 | 1.8 | 190 | 635 | |||||
| 100 | 0.2 | 1.65 | 1.6 | 215 | 710 | |||||
| 125 | 0.24 | 1.98 | 1.5 | 250 | 840 | |||||
| 160 | 0.29 | 2.42 | 1.4 | 285 | 945 | |||||
| 200 | 0.33 | 2.86 | 1.3 | 340 | 1125 | |||||
| 250 | 0.4 | 3.35 | 1.2 | 390 | 1295 | |||||
| 315 | 0.48 | 4.01 | 1.1 | 445 | 1475 | |||||
| 400 | 0.57 | 4.73 | 1 | 515 | 1712 | |||||
| 500 | 0.68 | 5.66 | 1 | 6 | 460 | 1995 | ||||
| 630 | 0.81 | 6.82 | 0.9 | 565 | 2450 | |||||
| 800 | 0.98 | 8.25 | 0.8 | 635 | 2765 | |||||
| 1000 | 1.15 | 11.33 | 0.7 | 840 | 3650 | |||||
| 1250 | 1.35 | 13.2 | 0.7 | 970 | 4220 | |||||
| 1600 | 1.63 | 15.95 | 0.6 | 1105 | 4800 | |||||
| 2000 | 1.95 | 19.14 | 0.6 | 1205 | 5240 | |||||
| 2500 | 2.34 | 22.22 | 0.5 | 1300 | 5650 | |||||
Generalakev sib twdrawv

Ib nrab - tiav 2 × 1450 KVA rectifier transformer

tiav 2 × 1450 KVA roj rectifier transformer

Cov khoom tseem ceeb ntawm cov roj immersed rectifier transformer
Transformer Lub Cev
Lub 2 × 1450 KVA roj immersed rectifier transformer plhaub yog tsim los ntawm siab - cov ntaub ntawv kub resistant, muab zoo heev overload kam rau ua, cuam tshuam, thiab rwb thaiv tsev. Cov khoom siv hluav taws xob tau teeb tsa hauv kev tshawb fawb, ua kom muaj txiaj ntsig zoo ntawm cov khoom siv hluav taws xob thiab ua kom muaj kev ruaj ntseg ntawm cov khoom siv.
Terminal
Lub siab -cov khoom siv hluav taws xob zoo tuaj nrog meej thiab yooj yim-kom- nkag siab cov lus qhia txuas, ua kom yooj yim rau kev teeb tsa. Cov roj immersed traction rectifier transformer lub zog thiab ruaj khov tsim zoo ua kom muaj kev ruaj ntseg thiab kev ntseeg siab ntawm kev sib txuas hluav taws xob.
Khoom siv tooj liab ntshiab
High -qib cov khoom siv tooj liab ntshiab yog siv, zoo kawg li txhim kho cov khoom siv kho tshuab, lub zog txhua yam, dynamic stability, thiab thermal stability ntawm cov cuab yeej, muab kev lav zoo rau kev ua haujlwm zoo.
Roj Qib ntsuas
Cov roj qib ntsuas ntawm cov roj immersed tam sim no transformer nta ib qho intuitive ob -xim zaub tsim: liab qhia cov roj qis, thaum xiav qhia txog qib ib txwm muaj. Cov roj theem xwm txheej pom tau meej meej, ua rau kev saib xyuas txhua hnub thiab saib xyuas tsis muaj zog.
Cov khoom siv kab ntau lawm

FAQ
Q: Koj cov khoom tseem ceeb yog dab tsi?
A: Peb cov khoom tseem ceeb suav nrog roj -immersed transformers, qhuav-hom transformers, transformer substations, thiab high voltage switchgear.
Q: Koj cov khoom puas tuaj yeem hloov kho?
A: Yog lawm. Muab cov kev xav tau sib txawv rau qhov voltage, zaus, thiab lwm yam tshwj xeeb thoob plaws lub teb chaws thiab cheeb tsam, peb tuaj yeem kho peb cov khoom kom tau raws li koj cov kev xav tau tshwj xeeb.
Q: Ntev npaum li cas kuv tuaj yeem cia siab tias tus nqi nqe?
A: Feem ntau, peb muab cov lus hais hauv 24 teev tom qab tau txais koj qhov kev nug.
Q: Lub sij hawm ua ntej thiab lub sijhawm xa khoom yog dab tsi?
A: Lub sijhawm ua haujlwm txawv raws li kev txiav txim kom muaj nuj nqis. Feem ntau, peb tuaj yeem xa hauv 15 hnub tom qab tau txais cov nyiaj them ua ntej. Raws li rau shipping, nws nyob ntawm qhov chaw.
Q: Ntau npaum li cas shipping nqi?
A: Tus nqi thauj khoom sib txawv raws li qhov chaw nres nkoj xa khoom. Peb tuaj yeem muab cov lus qhia ntxaws ntxaws thaum qhov chaw pom tseeb.
Q: Koj cov khoom puas tuaj nrog warranty?
A: Yog lawm, tag nrho peb cov tshuab hloov pauv tuaj nrog qhov tsawg kawg nkaus - xyoo lav kom ntseeg tau tias muaj kev ntseeg siab thiab kev thaj yeeb nyab xeeb.
Q: Dab tsi ua rau koj lub tuam txhab sib nrug?
Peb qhov zoo tseem ceeb yog nyob rau hauv 18 xyoo ntawm kev paub hauv kev lag luam hluav taws xob thiab kev faib hluav taws xob. Peb tau nruab nrog lub xeev - ntawm -- cov chaw tsim khoom kos duab, ua kom cov khoom zoo sib xws, muab kev xa sai, thiab muab kev pabcuam tshaj lij thiab ua haujlwm. Tsis tas li ntawd, peb muab cov khoom seem dawb pub dawb los txhawb koj lub sijhawm ua haujlwm ntev -.
Cim npe nrov: 2 × 1450 kva roj immersed rectifier transformer, Tuam Tshoj 2 × 1450 kva roj immersed rectifier transformer manufacturers, lwm tus neeg, Hoobkas
Xa kev nug
Koj Tseem Yuav Zoo Li