Qhov kawg Qhia rau 1000 kVA Roj Immersed Transformer
Apr 08, 2026
Tso lus
1000 kVA roj immersed transformeryog ib qho ntawm feem ntau siv hluav taws xob faib kev daws teeb meem rau kev lag luam, kev lag luam, thiab kev siv hluav taws xob. Paub txog nws cov kev ua haujlwm siab, ua haujlwm ntev, thiab ua haujlwm txias txias, nws ua lub luag haujlwm tseem ceeb hauv kev nqis qis nruab nrab ntawm qhov hluav taws xob mus rau qhov siv tau qis qis.
Cov lus qhia no yuav pab koj nkag siab txhua yam los ntawm cov hauv paus ntsiab lus ntawm kev ua haujlwm mus rau cov txheej txheem xaiv - kom ntseeg tau tias koj xaiv lub transformer rau koj qhov project.
Dab tsi yog 1000 kVA Roj Immersed Transformer?
A 1000 kVA roj immersed transformeryog ib qho khoom siv hluav taws xob uas hloov hluav taws xob hluav taws xob ntawm cov hluav taws xob los ntawm electromagnetic induction. Nws siv cov roj insulating rau ob qho tib si txias thiab rwb thaiv tsev.

- Rated Peev XwmHwj chim: 1000 kVA
- Muaj nuj nqi: Kauj ruam- nqis los yog kauj ruam- nce voltage
- Txoj kev txias: Roj-raws li (feem ntau ONAN)
- Daim ntawv thov: Nruab nrab-voltage fais fab faib
Txoj Cai Ua Haujlwm ntawm Roj Immersed Transformers
Lub transformer ua haujlwm raws li electromagnetic induction:
- Thaum alternating tam sim no ntws los ntawm thawj winding, nws tsim ib tug magnetic teb.
- Qhov no magnetic teb induces voltage nyob rau hauv lub thib ob winding.
- Cov roj ua raws li ib qho insulator thiab dissipates tshav kub generated thaum lub sij hawm ua hauj lwm.
- Qhov no yooj yim tab sis muaj txiaj ntsig mechanism ua kom ntseeg tau thiab txuas ntxiv lub zog.
Cov Cheebtsam tseem ceeb ntawm 1000 kVA Roj Immersed Transformer
Core: Ua los ntawm laminated silicon steel kom txo qhov poob
Cua txias: Copper los yog aluminium coils
Transformer Roj: Muab rwb thaiv tsev thiab cua txias
Tank: Tiv thaiv cov khoom siv sab hauv thiab tuav cov roj
Radiators: Txhim kho cua sov dissipation
Tus neeg saib xyuas: Tswj cov roj qib
Buchholz Relay: Nthuav cov kev ua txhaum sab hauv

1000 KVA Transformer Specification
| Parameter | Tus nqi |
|---|---|
| Rated Peev Xwm | 1000 kVA ua |
| Thawj Voltage | 6 kV / 10 kV / 11 kV / 33 kV |
| Secondary Voltage | 0,4kv ua |
| Ntau zaus | 50 Hz / 60 Hz |
| Txoj kev txias | ONAN |
| Vector Group | Dyn11/Yyn0 |
| Impedance | 4% – 6% |
| Cov qauv | IEC / ANSI / GB |
Qhov zoo ntawm 1000 kVA Roj Immersed Transformers
- Ua haujlwm siab: Tsawg tsis muaj -load thiab load poob
- Txias zoo heev: Roj ua kom ruaj khov kub tswj
- Ntev Lifespan: Feem ntau 20-30 xyoo lossis ntau dua
- Muaj peev xwm overload: Haum rau hnyav - daim ntawv thov
- Tus nqi -Cov: Tus nqi qis dua piv rau qhuav- hom transformers
Daim ntawv thov ntawm 1000 kVA Roj Immersed Transformers
Cov transformers yog dav siv nyob rau hauv:
- Muaj cov nroj tsuag thiab factories
- Cov tsev lag luam thiab cov khw
- Fais fab faib tes hauj lwm
- Renewable zog tej yaam num (hnub ci & cua)
- Mining thiab hnyav kev lag luam
Yuav ua li cas xaiv txoj cai 1000 kVA Roj Immersed Transformer
Thaum xaiv lub transformer, xav txog cov hauv qab no:
- Voltage Requirements: Sib phim thawj thiab theem nrab voltage
- Load Demand: Xyuas kom 1000 kVA ua tau raws li koj lub zog xav tau
- Installation Ib puag ncig: Sab hauv lossis sab nraum zoov
- Kev xav tau cua txias: ONAN lossis yuam kom txias xaiv
- Kev Ua Raws Cai: IEC, ANSI, lossis cov qauv hauv zos
- Customization Xav tau: Kais changer, vector pawg, impedance
Cov lus qhia txog kev txhim kho thiab tu
Cov Txheej Txheem Txhim Kho
- Ua kom lub hauv paus ruaj khov thiab qib
- Muab qhov chaw tso cua txaus
- Khaws cov av kom raug
- Xyuas cov roj theem ua ntej commissioning
- Tshawb xyuas txhua qhov kev sib txuas hluav taws xob

Cov tswv yim tu
- Tsis tu ncua xyuas cov roj zoo thiab qib
- Saib xyuas qhov kub thiab txias
- Ua qhov ntsuas hluav taws xob niaj hnub
- Xyuas seb puas los yog corrosion
Tej teeb meem thiab kev daws teeb meem
Kub kub
Ua rau: Tshaj dhau los yog qhov cua tsis zoo
Kev daws: Txo cov load thiab txhim kho cov cua txias
Roj Leakage
Ua rau: Seal aging lossis tank puas
Kev daws: Hloov cov ntsaws ruaj ruaj thiab kho lub tank
Rwb thaiv tsev tsis ua hauj lwm
Ua rau: Moisture lossis aging oil
Kev daws: roj pom lossis hloov pauv
FAQ - 1000 kVA Roj Immersed Transformer
Dab tsi yog qhov ua tau zoo ntawm 1000 kVA roj immersed transformer?
Kev ua tau zoo feem ntau tshaj 98% raws li kev ua haujlwm ib txwm muaj.
Lub 1000 kVA transformer kav ntev npaum li cas?
Nrog kev tu kom zoo, nws tuaj yeem kav 20-30 xyoo lossis ntau dua.
Puas yog nws tsim nyog rau kev teeb tsa sab nraum zoov?
Yog, roj immersed transformers yog qhov zoo tagnrho rau qhov chaw sab nraum zoov.
Dab tsi yog qhov txawv ntawm cov roj immersed thiab qhuav hom transformers?
Roj immersed transformers muab cov cua txias zoo dua thiab muaj peev xwm ntau dhau, thaum hom qhuav muaj kev nyab xeeb dua rau kev siv sab hauv tsev.
Lub transformer puas tuaj yeem kho tau?
Yog, qhov voltage, impedance, thiab configuration tuaj yeem raug kho.
Lub peev xwm thauj khoom ntawm 1000 kVA transformer yog dab tsi?
Rau 1000kVA transformer, qhov siab tshaj plaws load nyob ntawm ntau yam xws li qhov ntsuas hluav taws xob, kev teeb tsa winding, cua txias, thiab qhov kub thiab txias. Feem ntau, 1000kVA transformer tuaj yeem tswj tau qhov siab tshaj plaws ntawm ib puag ncig800-850 kW
Muaj pes tsawg amps yog 1000 kVA transformer zoo rau?
Ib qho 1000 kVA transformer feem ntau yog siv rau hauv cov txheej txheem ntawm kev hloov cov kab siab -voltage fais fab mov mus rau qhov qis -voltage fais fab mov kab. Nws siv kilovolt-amperes ua cov ntsuas ntsuas rau lub tshuab hluav taws xob pom tseeb (kVA). Nws muaj peev xwm tiv taus qhov hluav taws xob ntawm 120 thiabib 8333.
Dab tsi yog qhov impedance ntawm 1000 kVA transformer?
Pad Mounted Transformers: Lub impedance ntawm 1000 kVA ncoo mounted transformers yog feem ntau nyob rau hauv ntau yam ntawm5% mus rau 6%, ntsuas kev ua tau zoo thiab kev ua txhaum cai rau kev siv sab nraum zoov thiab kev lag luam.
1000 kVA transformer muaj pes tsawg kW?
Yog li, 1000 kVA transformer tuaj yeem xa kwv yees li 800 kW ntawm lub zog tiag tiag ntawm lub zog ntawm 0.8.
Dab tsi yog qhov cua sov ntawm 1000 kVA transformer?
Transformers hloov hluav taws xob fais fab nrog ~ 98% efficiency. Qhov seem 2% hloov mus rau hauv tshav kub. Rau 1000 kVA unit, uas yog~ 20 kWmntawm tshav kub tas li dumped rau hauv chav tsev.
Vim li cas thiaj xaiv GNEE li koj tus Transformer Supplier?
- Muaj peev xwm tsim muaj zog
- Kev soj ntsuam nruj nruj system
- OEM & ODM kev cai
- Kev xa khoom sai thiab xa tawm thoob ntiaj teb
- Ua tiav daim ntawv pov thawj thiab kev txhawb nqa
Tau txais ib nqe lus tam sim no
Nrhiav kev txhim khu kev qha1000 kVA roj immersed transformer tsum?
Hu rau GNEE hnub no kom tau txais tus nqi sib tw, kev txhawb nqa kws tshaj lij, thiab kev daws teeb meem rau koj qhov project.