Rwb thaiv tsev Performance and Temperature Rise Test of 1000 kVA Oil-Immersed Transformer
Apr 13, 2026
Tso lus
Hauv kev faib hluav taws xob, kev ntseeg siab ntawm lub transformer yog tsim los ntawm kev sim. Rau 1000 kVA roj-immersed transformer, ob lub zog txiav txim siab txog kev pabcuam lub neej thiab kev nyab xeeb ntawm chav tsev: kev ncaj ncees ntawm lub rwb thaiv tsev thiab qhov kub thiab txias nce nyob rau hauv rated load. Ob leeg raug txheeb xyuas los ntawm cov qauv kev xeem, feem ntau yog cov uas tau teev tseg hauv IEC 60076, thiab ob qho tib si yuav tsum tau tshuaj xyuas kom zoo thaum lub tshuab hloov hluav taws xob tau teev tseg rau sab nraum zoov lossis kev lag luam.
Vim li cas Insulation thiab Kub Rise Testing Matters
Cov txheej txheem rwb thaiv tsev ntawm cov roj-immersed transformer muab cov rwb thaiv tsev ua kua (transformer roj) thiab cov khoom rwb thaiv tsev (cov ntawv cellulose thiab cov ntawv xovxwm). Nws yuav tsum tiv tsis tau tsuas yog qhov kev khiav hauj lwm tsis tu ncua tab sis kuj tseem nyob dhau -voltages los ntawm xob laim thiab kev hloov pauv. Kev ntsuas kub nce siab, dhau los, ua pov thawj tias lub tshuab hloov pauv tuaj yeem nqa nws cov khoom ntsuas yam tsis muaj lub rwb thaiv tsev degrading ntxov: lub tshav kub tsim los ntawm kev thauj khoom poob hauv cov windings thiab tsis muaj -load poob rau hauv cov tub ntxhais yuav tsum tau dissipated los ntawm cov cua txias kom qhov kub - qhov chaw kub nyob rau hauv qhov txwv uas tiv thaiv daim ntawv rwb thaiv tsev.
Lub rwb thaiv tsev ntawm 1000 kVA Roj-Immersed Transformer
Cov roj ua haujlwm ob txoj haujlwm: nws insulates lub windings ntawm ib leeg thiab los ntawm lub tank, thiab nws nqa cua sov mus rau qhov chaw txias. Khoom rwb thaiv tsev (daim ntawv, pressboard thiab lwm yam khoom siv cellulose) muab cov neeg kho tshuab thiab dielectric qauv ntawm winding rwb thaiv tsev. Ob qhov kev tsim cov ntsiab lus tseem ceeb rau kev rwb thaiv tsev zoo:
High-cov roj nqus cov pa nqus tau tshem tawm cov huab cua thiab noo noo los ntawm lub rwb thaiv tsev ua ntej cov roj nkag, tshem tawm cov hnab ntim cua uas tuaj yeem pib tawm ib nrab.
Precision winding tswj qhov nro thiab txheej sib nrug ntawm cov neeg xyuas pib kom cov ntawv rwb thaiv tsev siv tau tusyees thiab winding yog mechanically ruaj khov.
High-purity ntxhia roj nrog lub zog dielectric siab muab lub zog tiv thaiv hluav taws xob tawg, thiab cov roj oxidation stability ua rau cov rwb thaiv tsev ua haujlwm ruaj khov nyob rau ntau xyoo ntawm kev pabcuam.
Kev ntsuas kub nce siab rau IEC 60076
Thaum lub sij hawm ntsuas kub nce, lub transformer yog loaded nrog nws tag nrho cov poob (tsis muaj-load ntxiv load poob) kom khov kho- xeev kub tau mus txog, thiab saum- roj kub nce thiab qhov nruab nrab winding kub nce yog ntsuas. IEC 60076 teeb tsa cov kev txwv ib txwm:
Sab saum toj- roj kub nce: 60 K saum toj ib puag ncig.
Qhov nruab nrab winding kub nce: 65 K saum ambient.
Cov kev txwv no sib raug rau qhov tsim kub - qhov kub thiab txias uas ua rau cov cellulose rwb thaiv tsev tsis txhob nkim, uas yog lub ntsiab aging mechanism ntawm rwb thaiv tsev. Lub transformer uas nyob rau hauv cov kev txwv no thaum lub sij hawm xeem yuav muab lub neej kev pab cuam lub neej ntawm nws rated load. Rau qhov siab dua qhov kub thiab txias, qhov tso cai nce yuav tsum raug txo kom raws li, los yog qhov chaw txias kom loj.
Cov Cheebtsam Uas Tswj Thermal Performance
Yuav kom dhau qhov ntsuas kub nce siab, ntau qhov chaw ntawm lub transformer yuav tsum tau tsim los ua ib qho system:
Radiators thiab cua txias fins: lawv qhov chaw saum npoo yog xam los ntawm tag nrho cov poob thiab qhov kub thiab txias, thiab lawv yog thawj qhov kev tshem tawm cua sov hauv ONAN (Oil Natural, Air Natural) txias.
Transformer roj: lub tshav kub-hloov nruab nrab; nws viscosity thiab thermal zog txiav txim siab lub ntuj ncig tus nqi.
Lub tank: tsim los txhawb cov nyhuv thermosiphon, qhov twg cov roj kub nce thiab cov roj txias rov qab los, tswj cov kev khiav mus tas li los ntawm cov radiators.
Gaskets thiab cov ntsaws ruaj ruaj: siab-kub- cov ntaub ntawv tiv thaiv tiv thaiv kom tsis txhob xau thaum lub sijhawm nthuav dav thiab kev sib cog lus ntawm kev pabcuam sab nraum zoov.
Tej yam kev qhia tshwj xeeb
| Technical Parameter | Specification Tus nqi |
|---|---|
| Rated peev | 1000 kVA ua |
| Hom | Peb theem, roj raus, kauj ruam - nqis |
| High voltage (HV) | 6 kV, 10 kV, 11 kV, 22 kV, 33 kV |
| Tsawg voltage (LV) | 0.4 kV, 0.415 kV, 0.48 kV |
| Rwb thaiv tsev theem | LI 75 / AC 28 (tus qauv 10kV chav kawm) |
| Sab saum toj - roj kub nce | Tsawg dua lossis sib npaug li 60 K |
| Winding kub nce | Tsawg dua lossis sib npaug li 65 K |
| Txoj kev txias | ONAN |
| Roj hnyav | Kwv yees li . 550-650 kg |
| Tag nrho qhov hnyav | Kwv yees li . 2450 kg |
Advanced Insulation Options
Cov khoom siv ua ntej tso cai rau lub rwb thaiv tsev kom raug thawb ntxiv yam tsis muaj kev cuam tshuam txog kev nyab xeeb. Thermally upgraded ntawv tuaj yeem ua haujlwm ntawm qhov kub thiab txias me ntsis rau tib qhov kev laus, uas ua rau kom muaj peev xwm dhau ntawm chav tsev. Rau kev teeb tsa nrog hluav taws kub siab- kev nyab xeeb lossis ib puag ncig yuav tsum tau ua, ester kua (xws li ntuj thiab hluavtaws esters) yog lwm txoj hauv kev rau cov roj ntxhia: lawv muaj qhov taw tes siab dua thiab biodegradable, uas ua rau lawv tsim nyog rau qhov chaw rhiab heev thaum txhim kho lub rwb thaiv tsev lub neej ntawm lub transformer.
FAQ
Dab tsi yog qhov ntsuas kub nce rau 1000 kVA roj immersed transformer?
Raws li IEC 60076, cov kev txwv ib txwm yog 60 K rau sab saum toj - roj kub nce thiab 65 K rau qhov nruab nrab cua kub nce siab tshaj qhov ntsuas qhov ntsuas kub. Tus qauv tsim transformer yuav tsum ua kom ntsuas qhov nce siab hauv cov txiaj ntsig ntawm cov ntsuas ntsuas.
Vim li cas qhov ntsuas kub nce siab tseem ceeb?
Qhov kev ntsuam xyuas xyuas tias lub tshuab cua txias tuaj yeem tshem tawm cov cua sov uas tsim los ntawm tag nrho cov kev poob ntawm cov khoom ntsuas. Yog tias qhov kub thiab txias siab dhau lawm, cov ntawv rwb thaiv tsev muaj hnub nyoog sai thiab lub neej ntawm transformer luv luv.
Qhov rwb thaiv tsev qib LI 75 / AC 28 yog dab tsi?
Nws yog cov txheej txheem rwb thaiv tsev rau 10 kV chav kawm transformer: LI 75 txhais tau tias lub winding withstands 75 kV ncov xob laim impulse voltage, thiab AC 28 txhais tau tias nws tiv taus 28 kV fais fab - zaus kuaj voltage. Qib tau txhais hauv IEC 60076-3.
ONAN txias txoj kev ua haujlwm li cas?
ONAN stands rau Roj Ntuj, Huab Cua Ntuj: cov roj circulates ib txwm los ntawm convection (thermosiphon) los ntawm lub tank thiab radiators, qhov twg tshav kub raug tshem tawm los ntawm ntuj huab cua. Tsis siv lub twj tso kua mis lossis kiv cua, yog li cov cua txias yog qhov yooj yim thiab txhim khu kev qha.
Puas tuaj yeem ester kua hloov cov roj ntxhia hauv 1000 kVA transformer?
Yog lawm. Ester kua yog siv los ua lwm yam rau cov roj ntxhia uas muaj kev nyab xeeb hluav taws lossis kev tiv thaiv ib puag ncig yog qhov tseem ceeb. Lawv muaj qhov taw tes siab dua thiab yog biodegradable, tab sis tus tsim transformer yuav tsum suav rau lawv qhov sib txawv txias thiab dielectric zog.
Cov kev ntsuam xyuas niaj hnub ua li cas rau ntawm 1000 kVA roj immersed transformer?
Cov kev ntsuam xyuas niaj hnub ntawm IEC 60076 suav nrog kev ntsuas qhov ntsuas cua, qhov sib piv thiab vector pawg txheeb xyuas, tsis muaj -load poob thiab tsis muaj-load tam sim no, load poob thiab impedance voltage, cais- qhov chaw thiab induced AC tiv thaiv kev xeem, thiab roj dielectric xeem. Hom kev ntsuam xyuas kuj tseem npog qhov kub nce thiab xob laim impulse.