2000 kVA Nruab Nrab Voltage Qhuav Hom Transformer 12470V rau 480Y 277V Peb Theem North America

Jan 21, 2026

Tso lus

2000 kVA Nruab nrab-Voltage Qhuav-Hom Transformer

Qhov no 2000 kVA nruab nrab-voltage qhuav- hom transformer yog tsim los rau kev nyab xeeb, siab -kev ua tau zoo thiab kev saib xyuas- ua haujlwm pub dawb thoob plaws ntau yam kev lag luam, kev siv hluav taws xob thiab chaw tsim khoom. Kev khav theeb thawj qhov hluav taws xob ntawm 12470V thiab qhov hluav taws xob thib ob ntawm 480Y / 277V, nws yog qhov kev daws teeb meem zoo tshaj plaws rau qib voltage- nqis hauv nruab nrab-voltage fais fab phiaj.

 

Tsim los nrog qib siab - qib silicon steel cores thiab precision tooj liab windings, qhov qhuav no -hom faib transformer muab qhov tshwj xeeb thermal kev ua tau zoo, qis zog poob thiab lub neej ntev kev pab cuam. Nws qhuav- hom rwb thaiv tsev ua kom muaj kev tiv thaiv hluav taws kub, xoom roj to, thiab ua haujlwm nyab xeeb hauv tsev lossis ib puag ncig rhiab.

 

Featuring lub zog, corrosion- tiv thaiv enclosure, qhov nruab nrab-voltage transformer yog ua raws li ANSI, IEEE, UL, CSA thiab CE cov qauv. Haum rau North thiab South American kev lag luam, nws muaj feem xyuam rau cov chaw siv hluav taws xob, cov tsev lag luam, cov phiaj xwm hluav taws xob tauj dua tshiab thiab kev lag luam hnyav, thiab lwm yam.

 

Raws li lub tuam txhab ua lag luam ntawm qhuav-hom transformers, GNEE muaj lub Hoobkas- cov khoom siv ncaj qha, OEM customization cov kev pabcuam thiab cov khoom lag luam txhim khu kev qha kom xa khoom sai. Peb pabcuam cov lag luam tseem ceeb suav nrog Tebchaws Meskas, Canada, Mexico, Brazil, Chile thiab Colombia, muab siab -kev ua haujlwm nruab nrab-voltage qhuav- hom transformers rau EPC cov neeg cog lus, wholesalers thiab hluav taws xob cog lus.

 

Medium-Voltage Dry-Type Transformer

Kawm ntxiv:1500 kVA 11kV rau 400V Roj Filled Peb Theem Distribution Transformer|IEC & ANSI Cov Qauv

 

✅ Txheej txheem cej luam ntawm 2000 kVA Nruab Nrab-Voltage Qhuav-Hom Transformer

Tsim los rau 12470V thawj sab thiab 480Y / 277V theem nrab, qhov no 2000 kVA nruab nrab-voltage qhuav- hom transformer yog dav siv hauv kev lag luam, kev lag luam thiab kev siv hluav taws xob faib hluav taws xob. Tsim los ntawm GNEE, nws yog eco- tus phooj ywg thiab hluav taws kub- retardant, featuring Class F/H rwb thaiv tsev, lub tshuab nqus tsev siab impregnation (VPI) txheej txheem thiab siab mechanical zog. Haum rau ob qho tib si sab hauv tsev thiab sab nraum zoov, nws txhawb nqa huab cua ntuj (AN) lossis cua txias (AF) txias, thiab ua raws li ANSI / IEEE C57.12, UL, CSA, CE thiab IEC 60076-11 cov qauv.

 

✅ Txhais lus ntawm 2000 kVA Medium-Voltage Dry-Type Transformer

Nruab nrab-voltage qhuav- hom transformers siv huab cua los yog epoxy resin es tsis txhob roj los insulate windings, txo qhov hluav taws kub txaus ntshai thiab ib puag ncig txaus ntshai. Qhov kev tsim no ua rau nws yog qhov kev xaiv zoo tshaj plaws rau cov tsev lag luam, tsev kho mob, tshav dav hlau, tunnels, lub zog txuas ntxiv hluav taws xob thiab lwm qhov chaw uas muaj kev ruaj ntseg hluav taws kub. Nws hloov cov hluav taws xob nruab nrab-voltage hluav taws xob (feem ntau 1 kV txog 35 kV) mus rau qhov siv tau tsawg- hluav taws xob hluav taws xob, ua kom muaj kev nyab xeeb thiab ruaj khov ntawm hluav taws xob xa hluav taws xob.

 

✅ Qhov zoo ntawm 2000 kVA Nruab Nrab-Voltage Qhuav-Hom Transformer

Qhuav- hom transformers tshem tawm qhov xav tau ntawm cov kua hluav taws xob hluav taws xob, yog li txhim kho kev nyab xeeb thiab txo tus nqi kho. Tiv thaiv kom tsis txhob ya raws, plua plav thiab tshuaj lom neeg, lawv tuaj yeem ua haujlwm nyob rau hauv qhov chaw hnyav lossis rhiab heev. Lawv modular, kaw qauv yooj yim rau kev thauj mus los thiab kev teeb tsa, thiab nrog cov cua kub zoo heev thiab cov suab nrov qis, lawv zoo tagnrho rau kev siv hauv nroog thiab sab hauv.

 

✅ Dimensions of 2000 kVA Medium-Voltage Dry-Type Transformer

Tej qhov ntev yuav txawv raws li tus qauv tsim thiab cov ntaub thaiv npog:

  • Ntev: 2000-2500 mm
  • Dav: 1200-1400 mm
  • Qhov siab: 1800-2100 mm
  • Net Nyhav: Approx . 4200–4800 kg

GNEE muab cov lus qhia ntxaws txog kev teeb tsa, cov qauv thauj tog rau nkoj thiab cov ntaub ntawv nqa cov ntsiab lus kom yooj yim installation.

 

Kawm ntxiv:750 kVA Distribution Transformer los ntawm Cov Tuam Txhab Tso Cai|13.2 kV rau 208Y / 120 V Peb-Theem Fais Fab

 

Medium-Voltage Dry-Type Transformer✅ Nyhav thiab tuav ntawm 2000 kVA Nruab Nrab-Voltage Qhuav-Hom Transformer

Shipping Nyhav: Kwv yees li . 4.5 txog 5.0 metric tons, nyob ntawm qhov loj me.

Mounting Options: Skid base, pem teb -mounted lossis rail-mounted installation muaj.

Lifting Points: Integrated tsim rau kev nyab xeeb thiab sib npaug hoisting.

GNEE ua kom muaj kev ruaj ntseg ntim thiab muab cov ncauj lus kom ntxaws txog kev nqa thiab cov neeg siv phau ntawv rau kev xa khoom zoo thiab kev teeb tsa.

 

✅ Nqe Ntawm 2000 kVA Nruab Nrab -Voltage Qhuav-Tom Transformer

Tus nqi ntawm 2000 kVA qhuav- hom transformer feem ntau yog li ntawm US $ 22,000 mus rau US $ 35,000, raws li cov khoom siv (tooj liab lossis txhuas), hom thaiv, khoom siv thiab cov ntawv pov thawj xaiv. GNEE muab lub Hoobkas- tus nqi ncaj qha, nrog cov nqe lus xa khoom suav nrog EXW, FOB thiab CIF muaj.

 

✅ Txoj Kev Txias ntawm 2000 kVA Nruab Nrab -Voltage Dry-Type Transformer

AN (Air Natural): Txheem convection txias rau cov xwm txheej load

AF (Air Forced): Forced cua txias rau overload los yog kub ambient kub

Dual Cooling: Muab AN thiab AF cua txias kom hloov mus rau qhov sib txawv ntawm qhov yuav tsum tau ua.

 

✅ Kev Tiv Thaiv thiab Saib Xyuas Kev Xaiv rau 2000 kVA Nruab Nrab -Voltage Qhuav- Hom Transformer

  • Digital kub sensors (PT100 / PTC) nrog lub tswb muaj nuj nqi
  • Tsis siv neeg kiv cua controllers rau AF-cov qauv txias
  • Kev saib xyuas tej thaj chaw deb ntawm RS485 lossis Modbus RTU
  • Surge protectors thiab grounding systems suav nrog
  • Seismic thiab anti- kev co mounting xaiv muaj

 

Kawm ntxiv:500 kVA 11kV / 0.4kV Roj-Filled Electrical Distribution Transformer - Lub Hoobkas ncaj qha

 

✅ Khoom Series thiab Cov Qauv ntawm 2000 kVA Nruab Nrab-Voltage Qhuav-Hom Transformer

Standard Series: Cov qauv tsim muaj zog, tooj liab windings, nqi - zoo

Zog-Txuag Series: Tsawg- poob cores thiab cov khoom siv siab heev

Hwm Series: Suab nrov-txo, txhim kho txhua yam zog

Hom Kev Tiv Thaiv Harmonic: K- ntsuas rau tsis yog- cov kab hluav taws xob

Sab nraum zoov Enclosed Models: Weatherproof nrog IP23, IP44 lossis IP54 tiv thaiv chav kawm

Ntse Transformers: IoT- qhib rau lub sijhawm tiag tiag - saib xyuas lub sijhawm

 

✅ Vector pab pawg ntawm 2000 kVA Nruab Nrab-Voltage Qhuav-Hom Transformer

Feem ntau siv vector pawg:

Dyn 11: Txuj rau cov hluav taws xob faib hluav taws xob

Yyn 0: Rau kev sib npaug load daim ntawv thov

Yd11/Yz11: Rau daim phiaj synchronization yuav tsum

Kev cai vector pawg configurations muaj nyob rau ntawm kev thov.

 

info-374-374✅ Daim ntawv thov ntawm 2000 kVA Medium-Voltage Dry-Type Transformer

Industrial fais fab nroj tsuag

Cov tsev lag luam chaw ua haujlwm thiab khw muag khoom

Cov chaw siv hluav taws xob tauj dua tshiab (hnub ci, cua)

Tsev kho mob thiab chaw kho mob

Data centers thiab telecommunications hubs

Airports, subways thiab pej xeem kev thauj mus los

Utilities thiab substations

 

✅ 2000 kVA Medium-Voltage Qhuav-Hom Transformer Ua nyob rau hauv Suav teb nrog Kev Pov Hwm Zoo

Lub 2000 kVA qhuav- hom transformers tsim los ntawm GNEEr yog tsim nyob rau hauv Tuam Tshoj raws li nruj zoo tswj. Tag nrho cov khoom raug kuaj xyuas hauv lub Hoobkas, suav nrog kev ntsuas kev ua haujlwm dielectric, kev ntsuas kev thauj khoom thiab ntsuas kub nce, kom ua raws li IEC, ANSI, UL, CSA thiab CE cov qauv. Peb transformers pab cov neeg muas zaub nyob rau hauv North thiab South America, nrog ntau yam lus txhawb thiab ceev ceev cov sij hawm muab.

Kawm ntxiv: 1000 kVA 13.8 kV rau 208Y / 120 V Peb Theem Roj Immersed Distribution Transformer

 

Kev tsim khoom, kuaj, ntim thiab xa khoom thoob ntiaj teb ntawm 2000 kVA Nruab Nrab-Voltage Qhuav-Hom Transformer

Nrog rau thawj qhov hluav taws xob ntawm 12,470V thiab qhov hluav taws xob thib ob ntawm 480Y / 277V, qhov 2000 kVA nruab nrab -voltage qhuav- hom transformer yog qhov kev xaiv zoo tshaj plaws rau cov chaw tsim khoom, chaw lag luam, kev siv hluav taws xob thiab kev siv hluav taws xob tauj dua tshiab. GNEE saib xyuas tag nrho cov txheej txheem tsim khoom, suav nrog cov tub ntxhais lamination, precision winding, lub tshuab nqus tsev siab impregnation, sib dhos, kev tshuaj xyuas zoo thiab kev tiv thaiv ntim. Ua nyob rau hauv ISO- cov chaw tsim khoom muaj ntawv pov thawj thiab ua raws li UL, CE, CSA thiab IEC cov qauv, cov transformers no ua kom ntseeg tau tias kev ua tau zoo thiab kev nyab xeeb rau cov neeg siv khoom thoob ntiaj teb.

 

📩 Hu rau GNEE tam sim no kom paub meej cov lus qhia tshwj xeeb, CAD kos duab lossis cov lus hais haum rau koj 2000 kVA nruab nrab -voltage qhuav- hom transformer project.

 

✅ Hoobkas- tus nqi ncaj qha

✅ Cov ntawv pov thawj thoob ntiaj teb thiab kev pom zoo

✅ Kev ntseeg siab los ntawm cov neeg siv khoom hauv ntau dua 70 lub teb chaws

 

Thov Ib Daim Quote

 

2000 kVA ua12470V rau 480YNruab nrab Voltage Qhuav Hom TransformerTechnical Specs

Tsis muaj. Yam khoom Specification Lus hais
1 Kev ntsuas fais fab 2000 kVA ua Customizable ntawm 300 kVA mus txog 10000 kVA
2 Thawj Voltage 12470V (Delta txuas) Yeem: 4160V, 13800V, 34.5kV rau kev siv hluav taws xob
3 Secondary Voltage 480Y / 277V (Wye grounded) Lwm cov kev xaiv: 208Y / 120 V, 600Y / 347 V, 240 / 120 V split-theem
4 Theem Peb-phase, 60 Hz Muaj nyob rau hauv ib qho -theem lossis dual-voltage versions
5 Hom rwb thaiv tsev Hom Qhuav (VPI / VPE Resin Impregnation) Cua-insulated, roj-dawb, eco- lwm txoj kev phooj ywg
6 Rwb thaiv tsev Class Chav Kawm F (155℃standard) Upgradeable rau Chav H (180 degree) rau siab - qhov chaw kub
7 Kub nce 150℃(tus qauv) Kev xaiv 80 degree, 115℃rau kev txhim kho lub neej
8 Txoj kev txias Air Natural (AN) lossis Air Forced (AF) Haum rau siv sab hauv / sab nraum zoov raws li NEMA 3R
9 Qhov voltage impedance 5.5% – 6.5% Qhov project-raws li tuning muaj rau cov kev txwv tam sim no
10 Short Circuit Withstand 25-50 kA, 2 vib nas this Kev cai tiv taus qhov tseem ceeb muaj nyob ntawm kev thov
11 Voltage taps ± 2.5%, ± 5%, 4-6 kais Txhawb nqa ntawm -load lossis off-load kais hloov pauv xaiv
12 Ntau zaus 60 Hz Export qauv txhawb 50 Hz ua haujlwm
13 Rwb thaiv tsev Resistance Ntau dua lossis sib npaug li 1000 MΩ Txhim kho kev cia siab rau hauv qhov chaw ntub dej lossis plua plav
14 Leakage Magnetic Flux Tsawg-flux leakage core tsim Txo kev cuam tshuam nrog cov cuab yeej uas nyob ib sab
15 Cov khoom siv tseem ceeb High-qib nplej-qib silicon steel Txo kom tsis muaj-load poob, txhim kho txoj kev sib nqus flux
16 Cov khoom siv winding Copper (oxygen -dawb, siab conductivity) Yeem: aluminium winding rau tus nqi -sensitive tej yaam num
17 Cov ntaub ntawv enclosure Galvanized txias- dov steel Hmoov-coated, rustproof rau hnyav ib puag ncig
18 Kev tiv thaiv ntsuas NEMA 3R (tus qauv) Kuj muaj: NEMA 1, NEMA 12, IP44 / IP54 enclosures
19 Kev khiav hauj lwm qhov kub thiab txias -25℃rau +45 degree Ntxiv kev xaiv los ntawm -40℃mus rau +55℃muaj
20 Humidity Adaptability 0% mus rau 95%, tsis yog -condensing Zoo tagnrho rau ntug hiav txwv dej, chaw sov, lossis siab - thaj chaw av noo
21 Lub suab nrov Tsawg dua lossis sib npaug li 60 dB(A) Tsawg- suab nrov tsim rau tsev kho mob, tsev kawm ntawv, tsev
22 Kwv yees qhov hnyav 2600-3200 kg Raws li qhov kawg specs thiab accessories
23 Qhov Loj (L x W x H) Approx . 1800 x 1300 x 1850 mm Kev cai qhov ntau thiab tsawg raws li mounting los yog txias xaiv
24 Kev Ua Raws Cai Daim ntawv pov thawj UL, ANSI C57, IEEE C57.12, CSA C2, CE Muaj ntawv pov thawj rau Asmeskas, Canada, Brazil, Chile, Mexico, thiab lwm yam
25 Warranty 1-2 xyoo standard Kev ruaj ntseg txuas ntxiv thiab kev txhawb nqa lub neej muaj
26 Tej kev siv Kev lag luam infrastructure, txuas ntxiv fais fab nroj tsuag, industrial substations Qhov zoo tshaj plaws rau hnub ci ua liaj ua teb, chaw tsim khoom, thiab siv daim phiaj pej xeem
27 Kev Pabcuam Ntiaj Teb & Kev Pabcuam Factory ncaj qha, thoob ntiaj teb export Lub khw tseem ceeb: Tebchaws Asmeskas, Canada, Mexico, Brazil, Colombia, Chile, Peru, Argentina

Xa kev nug