B23R085 0.23mm Ultra-Low Loss Grain-Oriented Electrical Steel

Jun 11, 2026

Tso lus

B23R085yog qib premium ntawm Cold-Rolled Grain-Oriented (CRGO) hluav taws xob steel. Nws yog txhais los ntawm nws 0.23 hli nominal thickness thiab ib tug guaranteed siab tshaj plaws core poob ntawm 0.85 W / kg ntawm 1.7T / 50Hz. Cov khoom siv no yog ib qho tseem ceeb rau kev ua haujlwm siab - fais fab transformers thiab tis transformer cores, uas txo tsis muaj -load poob thiab txhim kho lub zog efficiency yog lub hom phiaj tseem ceeb tsim.

 

Raws li lub ntiaj teb lub zog- cov qauv kev ua tau zoo dhau los ua nruj zuj zus, B23R085 tau dhau los ua ib qho ntawm cov qib CRGO uas tau xaiv ntau tshaj plaws rau S13, S15, S20, thiab lwm yam siab - cov qauv hloov pauv tau zoo.

 

 

B23R085 CRGO electrical steel

B23R085 CRGO electrical steel  mtc

Nrhiav rau siab -zoo B23R085 CRGO hluav taws xob steel rau transformer manufacturing?

 

GNEE muab cov nplej- taw qhia hluav taws xob steel coils, slit coils, thiab txiav laminations nrog kev tswj xyuas nruj thiab cov kev xaiv hloov tau yooj yim. Nrog rau kev xa tawm hauv ntau dua 150 lub teb chaws, peb pab cov tuam txhab tsim hluav taws xob txo qis, txhim kho kev ua tau zoo, thiab txo qis kev xa khoom los ntawm kev xa khoom thoob ntiaj teb txhim khu kev qha thiab teb cov kev txhawb nqa.

 

Xa peb cov qib koj xav tau, thickness, dav, lossis kev thov txhua xyoo, thiab peb cov engineers yuav pom zoo tus nqi tshaj plaws -kev daws teeb meem zoo hauv 24 teev.

Thov Ib Daim Quote

 

Nkag siab txog B23R085 Specification

 

 

Lub npe ntawm B23R085 ua raws li cov qauv thoob ntiaj teb xws li IEC 60404 thiab cov chaw tsim khoom- cov qauv tshwj xeeb xws li Baosteel Q/BQB 480.

  • B: Baosteel hom.
  • 23: Nominal thickness 0.23 hli
  • R: Laser domain refined grain -oriented hluav taws xob hlau
  • 085: Cov tub ntxhais poob siab tshaj plaws P1.7/50 Tsawg dua lossis sib npaug rau 0.85 W / kg

 

Technical Specifications

KhoomTus nqiKev kuaj mob
Nominal Thickness0.23mm ib--
Qhov siab tshaj plaws Core poob P1.7/500.85 w/kg1.7T, 50Hz
Hom Sib Nqus Induction B81.88 T800 A/m
Lamination Factor>95.5%--
Txheej homInorganic insulating txheejC-5 los yog sib npaug

 

B23R085 Hluav taws xob steel Electromagnetic kev ua tau zoo tus qauv


Qib
Thickness (hli)Qhov ceev (kg / dm3)Qhov siab tshaj plaws hlau poob P15/50 (W / kg)Yam tsawg kawg nkaus sib nqus induction B8
B23R0850.237.650.851.87

 

B23R085 Hluav taws xob cov hlau sib npaug

BaoSteelWISCONSCJFECongentTKSPOSCONI&SCOAK
B23R085-23 TSI 85
23 ZPO 85
23 ZPO 85 H085-2323 PAB085--

 

GNEE Steel Grain -Silicon Steel Inventory

HomQibDavMax Core Loss@P1.7T/50HzLamination Factor (%)Min Induction @B800
Hom Hom23Q11035-1200 hli1.10 w/kg97.21.82T
23Q1201.20 w/kg97.21.82T
27Q1201.20 w/kg97.51.82T
30G1201.20 w/kg981.82T
Siab Induction
Hom
B20P08535-1200 hli0.85 w/kg971.86T
B23P0850.85 w/kg97.21.88T
B23P0900.90 w/kg97.21.88T
B23P0950.95 w/kg97.21.88T
B23P1001.00 w/kg97.21.88T
B27P0950.95 w/kg97.51.89T
B27P1001.00 w/kg97.51.89T
B30P1201.20 w/kg981.89T
Domain Refined High Induction
Hom (Laser)
B20R07035-1200 hli0.70 w/kg971.86T
B23R0850.85 w/kg97.21.88T
wb 27r0850.85 w/kg97.51.89T

 

High -Quality & Assembled Cores

  • Qhov hnyav tshaj plaws ntawm Tsis Siv Neeg Stacked Core: Ib qho zoo siab 60 Tons
  • Qhov hnyav tshaj plaws ntawm Manually Stacked Core: Ib qho muaj zog 120 Tons
  • Gap Limit ntawm Joint: Precision engineering ua kom muaj qhov sib txawv tsawg dua 1 hli
  • Qhov rai qhov siab Precision: Exacting standard yield a precision of ± 1mm
  • Qhov rai dav Precision: Unmatched precision nrog lub siab ntev ntawm ± 1mm

 

Vim li cas B23R085 Zoo dua li 0.30 hli CRGO Steel?

 

 

Ib qho ntawm cov laj thawj tseem ceeb ntawm transformer manufacturers xaiv B23R085 yog nws lub peev xwm los txo tag nrho cov tub ntxhais poob thaum tswj kev sib nqus zoo heev.

 

Lower Eddy Tam Sim No Loss

Eddy tam sim no poob yog proportional rau square ntawm steel thickness. Piv nrog cov pa 0.30 hli CRGO steel, lub thinner 0.23 hli ntsuas tau ua rau muaj kev cuam tshuam cov dej ntws hauv cov tub ntxhais.

Raws li qhov tshwm sim, B23R085 tuaj yeem txo qhov tsis muaj - thauj khoom poob los ntawm kwv yees li 15%–20% piv nrog cov laus- tiam CRGO cov ntaub ntawv siv nyob rau hauv cov qauv faib transformers.

 

Higher Transformer Efficiency

Lub hauv paus poob qis txhais tau hais tias lub zog hluav taws xob tsawg dua hloov mus rau hauv cov cua sov thaum ua haujlwm. Qhov no ncaj qha txhim kho transformer efficiency thiab txo qhov ntev -cov nqi khiav lag luam rau cov khoom siv hluav taws xob thiab cov neeg siv khoom lag luam.

 

Txo kev ua haujlwm kub

Los ntawm kev tsim hluav taws xob tsawg dua hauv cov tub ntxhais, B23R085 pab tswj kev ua haujlwm qis dua, uas tuaj yeem ua rau lub neej rwb thaiv tsev ntev dua thiab txhim kho kev ntseeg siab ntawm transformer.

 

Kev Tshawb Fawb Tom Qab 0.23 hli Thickness

 

 

Tag nrho cov tseem ceeb poob ntawm lub transformer muaj hysteresis poob thiab eddy tam sim no poob.

 

Eddy Kev Tiv Thaiv Tam Sim No

Txo cov thickness ntawm 0.30 hli mus rau 0.23 hli tsub kom hluav taws xob tiv thaiv nyob rau hauv laminations thiab ho txo ​​eddy tam sim no tiam.

 

Domain Refinement Technology

Ntau tus hwm B23R085 cov khoom lag luam tau txais laser domain refinement los yog kev kho deg zoo sib xws. Cov thev naus laus zis no txhim kho cov qauv sib nqus sib nqus thiab tso cai rau cov hlau nplaum sib nqus kom txav tau zoo dua los ntawm cov hlau.

 

High Magnetic Permeability

Nrog rau tus nqi sib nqus induction saum toj no 1.88 T, B23R085 tso cai rau cov transformer cores khiav lag luam ntawm cov flux ntau dua thaum tswj kev ua tau zoo thiab tsis txhob ua kom ntxov ntxov.

 

B23R085 vs B27R095 vs B30P105

 

 

Transformer designers feem ntau piv B23R085 nrog rau lwm cov nplej- taw qhia cov qib hluav taws xob steel.

QibThicknessCore Poob P1.7/50
B23R0850.23mm ib0.85 w/kg
B27R0950.27mm ib0.95 w/kg
B30P1050.30 hli1.05 W / kg

 

Ntawm 1.7T & 50Hz, B23R085 muaj nyob ib ncig ntawm 19% cov tub ntxhais poob qis dua B30P105, nrog sib npaug sib nqus ua haujlwm. Qhov no ua rau nws tshwj xeeb tshaj yog txaus nyiam rau lub zog-kev hloov pauv tau zoo.

0.23mm 0.85 0.85 W/Kg Electrical Steel mtc
0.23mm 0.85 0.85 W/Kg Electrical Steel mtc

B23R085 vs B23P085

 

 

Txawm hais tias ob qib muaj tib qhov tuab thiab qhov tseem ceeb - qhov qhab nia poob, lawv ua haujlwm sib txawv.

KhoomB23R085B23P085
HomTsis tu ncua GOSiab Permeability GO
Core Loss0.85 w/kg0.85 w/kg
Sib nqus PermeabilityTxujSiab dua
Transformer NoiseTxujqis
Tus nqi khoom sivqisSiab dua

Rau cov nqi qis- suab nrov transformers thiab ultra- siab- kev siv tau zoo, B23P085 feem ntau nyiam. Rau feem ntau lub hwj chim thiab kev faib transformers, B23R085 muab qhov sib npaug zoo ntawm tus nqi thiab kev ua haujlwm.

 

B23P085 mtc

 

Lub zog B23R085 tuaj yeem txuag tau ntau npaum li cas?

 

 

Qhov txo qis hauv qhov tsis muaj -load poob yuav tshwm sim me me rau ntawm daim ntawv, tab sis kev txuag hluav taws xob txuas ntxiv mus thoob plaws lub tshuab hloov pauv lub neej ua haujlwm.

 

Piv txwv li, yog hais tias ib tug 1000 kVA tis transformer txo tsis muaj -load poob los ntawm 150 W los ntawm kev siv B23R085, lub zog txuag txhua xyoo tuaj yeem tshaj:

  • 150 W × 24 teev × 365 hnub=1,314 kWh/xyoo

 

Tshaj li 25 xyoo kev pab cuam lub neej, qhov no tuaj yeem txhais tau ntau dua 32,000 kWh ntawm kev txuag hluav taws xob, pab kev siv hluav taws xob txo cov nqi khiav lag luam thiab cov pa roj carbon emissions.

 

Cov ntawv thov kev lag luam ntawm 0.23mm 0.85 0.85 W / kg hluav taws xob hlau

 

 

B23R085 yog dav siv nyob rau hauv kev lag luam uas lub zog efficiency thiab kev ntseeg tau yog ib qho tseem ceeb.

 

Ultra{0}}High Voltage (UHV) Transformers

Nws qis - cov yam ntxwv poob ua rau nws haum rau ntev - lub zog xa hluav taws xob.

 

Distribution Transformers

B23R085 feem ntau yog siv nyob rau hauv S13, S15, thiab lwm yam siab -vim transformer designs deployed nyob rau hauv niaj hnub lub nroog fais fab mov.

 

Instrument Transformers

Cov yam ntxwv zoo sib nqus muab kev ua haujlwm ruaj khov thiab ntsuas qhov tseeb.

 

Sib nqus Shielding Cheebtsam

Cov kev taw qhia sib nqus cov khoom ntawm cov nplej-oriented steel kuj ua rau B23R085 haum rau tshwj xeeb daim ntaub thaiv npog.

Ultra-High Voltage (UHV) Transformers
Distribution Transformers
dry type Transformers
Transformers core

Manufacturing thiab Quality Control

 

 

Ua B23R085 yuav tsum muaj cov txheej txheem metallurgical siab heev thiab kev tswj xyuas nruj.

 

Secondary Recrystalization

Cov neeg tsim khoom ua tib zoo tswj cov txheej txheem annealing los txhim kho qhov zoo tshaj plaws Goss Texture ((110) [001]), uas muab cov khoom sib nqus zoo tshaj plaws hauv cov kev taw qhia dov.

 

Rwb thaiv tsev txheej

Lub siab -tsis kam phosphate-raws li txheej txheej yog siv los tiv thaiv hluav taws xob tiv tauj ntawm laminations thiab txhim kho kev sib tsoo.

 

Kev Ntsuas Zoo

Txhua qhov ntau lawm batch tau soj ntsuam nruj rau:

  • Core poob
  • Sib nqus induction
  • Txheej adhesion
  • Thickness kam rau ua
  • Nto zoo

 

Xaus

 

 

B23R085 tau dhau los ua ib qho ntawm cov khoom siv rau cov khoom siv hluav taws xob niaj hnub no -cov hloov pauv tau zoo. Nws kev sib xyaw ua ke ntawm ultra-cov tub ntxhais poob qis, siab sib nqus induction, zoo permeability, thiab pov thawj ntev- lub sij hawm kev ntseeg tau ua rau cov tuam txhab tsim cov khoom me me, ntsiag to, thiab muaj txiaj ntsig zoo dua.

 

Rau cov tuam txhab transformer tsom rau cov qauv kev ua tau zoo dua thiab cov nqi qis dua lub neej, B23R085 tseem yog ib qho ntawm cov nqi ntau tshaj -cov qib CRGO hluav taws xob hlau zoo muaj hnub no.

 

CRGO electrical steel

CRGO electrical steel

 

Xav tau cov lus hais rau B23R085 CRGO steel?

Txawm hais tias koj xav tau tag nrho cov coils, slit coils, lossis cov khoom siv hloov pauv hloov pauv, GNEE tuaj yeem muab cov nqi sib tw Hoobkas, daim ntawv pov thawj zeb xeem, thiab cov sijhawm xa khoom sai.

 

Ntau tus neeg siv khoom pom tias xaiv cov qib CRGO txoj cai tuaj yeem txo qhov hloov pauv tsis muaj -load poob los ntawm 10–20% thaum txo nqi tag nrho. Hu rau peb pab neeg hnub no kom muaj kev sib tham pub dawb thiab cov lus hais raws li koj qhov project xav tau

 

 

B23R085 CRGO steel

 

Tau txais ib nqe lus

 

B23R085 packaging

 

Cov lus nug nquag

 

 

Qhov txawv ntawm B23R085 thiab B23P085 yog dab tsi?

Ob qib muaj tib lub thickness thiab cov tub ntxhais - qhov qhab nia poob. Txawm li cas los xij, B23P085 yog qib siab -permeability qib uas feem ntau muab cov suab nrov qis dua thiab ua haujlwm zoo sib nqus.

 

Puas yog B23R085 haum rau Fais fab Transformers?

Yog lawm. B23R085 yog dav siv nyob rau hauv lub hwj chim transformers, tis transformers, thiab lub zog -hloov transformer cores.

 

B23R085 Yuav Ua Li Cas Thiaj Li Muaj Zog?

Nws cov tub ntxhais uas tsis tshua muaj kev poob qis txo cov nqi hluav taws xob hloov mus rau hauv cov cua sov, txhim kho transformer efficiency thiab txo cov nqi khiav lag luam.

 

B23R085 puas tuaj yeem txo cov suab nrov Transformer?

Piv nrog cov qauv CRGO cov qhab nia, B23R085 tuaj yeem pab txo qis kev co thiab suab nrov. Txawm li cas los xij, siab siab - qib permeability xws li B23P085 feem ntau muab cov suab nrov zoo dua.

 

Dab tsi yog Magnetic Induction ntawm B23R085?

Hom B800 sib nqus induction qhov tseem ceeb yog 1.88 Tesla lossis siab dua, nyob ntawm cov chaw tsim khoom.

 

Puas yog B23R085 Muaj nyob rau hauv Slit Coils?

Yog lawm. Feem ntau cov tuam txhab loj CRGO tuaj yeem muab B23R085 hauv coils, slit coils, thiab txiav laminations raws li qhov yuav tsum tau ua ntawm transformer.

 

Xa kev nug