630 kVA Roj-Filled Transformer: Cov ntaub ntawv qhia, Cov txheej txheem txias thiab kev siv
Jan 22, 2026
Tso lus
Dab tsi yog 630 kVA Roj-Filled Transformer?
A 630 kVA roj- puv transformer yog peb -theem tis transformer uas siv cov roj insulating rau cua txias thiab dielectric tiv thaiv. Cov roj circulates ib txwm, los yog raug yuam los ntawm twj thiab kiv cua, kom dissipate tshav kub los ntawm cov tub ntxhais thiab windings, kom ntseeg tau ruaj khov kev ua tau zoo nyob rau hauv tas li ntawd thiab fluctuating loads. Qhov ntsuas 630 kVA zaum ntawm ciam teb ntawm cov chaw faib me me thiab cov chaw hloov hluav taws xob loj dua, uas ua rau nws yog ib qho ntawm cov kev qhia dav dav tshaj plaws rau cov chaw tsim khoom, chaw ua lag luam, kev siv hluav taws xob thiab kev tsim kho vaj tse. Nws muaj peev xwm thauj khoom muaj zog, kev ua haujlwm zoo rwb thaiv tsev thiab ntev - lub sij hawm kev ntseeg tau piav qhia nws qhov chaw nyob hauv nruab nrab - muaj peev xwm faib hluav taws xob.
Cov ntaub ntawv qhia tshwj xeeb
| Parameter | Hom Specification |
|---|---|
| Rated peev | 630 kVA ua |
| Theem | Peb -theem |
| Thawj qhov voltage | 10 kV / 11 kV / 20 kV / customized |
| Secondary voltage | 0.4 kV lossis customized |
| Ntau zaus | 50 Hz / 60 Hz |
| Rwb thaiv tsev chav kawm | Chav Kawm A (roj-immersed system) |
| Txoj kev txias | ONAN tus qauv; ONAF yeem |
| Vector pawg | Dyn11, Yyn0 los yog lwm yam |
| Qhov voltage impedance | Txog 4.5-6% nyob ntawm qhov tshwj xeeb |
| Cov qauv tsim | IEC 60076, ANSI C57, GB 1094 / GB 20052-2024 |
Qhov kev teeb tsa kev ua haujlwm no ua rau lub tshuab hluav taws xob tsim nyog rau ob qho tib si kev lag luam thiab kev siv hluav taws xob, thiab cov txiaj ntsig tuaj yeem hloov mus rau qhov tshwj xeeb voltage thiab poob qhov yuav tsum tau ua ntawm qhov project.
Cov txheej txheem txias: ONAN thiab ONAF
ONAN (roj ntuj, huab cua ntuj)
ONAN yog tus txheej txheem cua txias rau 630 kVA roj-filled transformer. Cov roj rhuab nce los ntawm cov tub ntxhais thiab windings, ntws mus rau hauv lub radiator lossis corrugated tank, txias tawm tsam huab cua thiab rov qab los ntawm lub ntiajteb txawj nqus. Qhov kev ncig ntuj no yuav tsum tsis muaj cov cuab yeej pabcuam, uas ua rau tus qauv tsim tau yooj yim, txhim khu kev qha thiab txij nkawm- tus phooj ywg. Cov txiaj ntsig poob raug raug xa mus rau qhov txias txias no, thiab lub tshuab hloov pauv ua tiav nws qhov peev xwm nyob rau hauv ONAN ntawm 40℃ambient.
ONAF (roj ntuj, cua yuam)
Rau kev xav tau ntau dua, ONAF ntxiv cov kiv cua uas quab yuam huab cua hla lub tshuab hluav taws xob saum npoo av, ua kom cov cua sov tsis kam thiab tso cai rau lub tshuab hluav taws xob kom nqa lub nra hnyav dua, feem ntau 115-133% ntawm ONAN ntsuas. ONAF yog qhov muaj txiaj ntsig zoo thaum lub tshuab hloov pauv yuav tsum them rau qhov kev loj hlob ib ntus lossis lub caij nyoog siab tshaj yam tsis tau hloov lub tsev. Cov kiv cua xav tau kev tswj xyuas Circuit Court thiab kev saib xyuas ib ntus, tab sis lawv txuas ntxiv kev ua haujlwm yooj yim ntawm kev teeb tsa.
Qhov Zoo Tshaj Plaws
High load peev thiab lub zog efficiency
Qhov zoo tshaj plaws tsim qauv, ua nrog siab -qib nplej- taw qhia silicon steel, thiab siab- zoo tooj liab windings kom tsis muaj - load thiab load poob qis. Raws li lub zog txuag hluav taws xob ntawm GB 20052-2024, chav kawm poob ntawm 630 kVA chav tsev yog txhais los ntawm nws qhov tsis muaj kev thauj khoom thiab kev txwv tsis pub thauj khoom, uas cov neeg yuav khoom yuav tsum lees paub tiv thaiv qib uas xav tau rau lub khw muag khoom.
Muaj zog rwb thaiv tsev thiab kev nyab xeeb kev ua haujlwm
Transformer roj muab zoo heev dielectric zog, tiv thaiv cov windings thiab ua kom ruaj khov kev lag luam txawm nyob rau hauv ib puag ncig plua plav los yog ntub dej. Cov khoom siv tiv thaiv tus qauv suav nrog Buchholz relay, cov cuab yeej tiv thaiv siab, ntsuas roj kub thiab lub tshuab nqus pa uas siv lub tshuab nqus tsev.
Lub neej ua haujlwm ntev thiab kev saib xyuas qis
Cov roj tso tsheb hlau luam kaw thiab corrosion-cov qauv tiv thaiv tiv thaiv lub rwb thaiv tsev los ntawm oxygen thiab noo noo. Kev saib xyuas niaj hnub yog txwv rau kev sim roj ib ntus, tshuaj xyuas cov gaskets thiab bushings, thiab kev txheeb xyuas cov cuab yeej tiv thaiv, uas ua rau tag nrho cov nqi ntawm cov tswv cuab qis dua li 25 xyoo tsim lub neej.
Daim ntawv thov
Lub 630 kVA roj- puv transformer yog siv dav hauv cov chaw tsim khoom thiab chaw tsim khoom, chaw ua lag luam thiab cov chaw khaws ntaub ntawv, cov chaw siv hluav taws xob thiab cov chaw faib khoom, thiab cov kev tsim kho vaj tse thiab kev tsim kho. Nws lub peev xwm nruab nrab yog qhov zoo tagnrho rau cov chaw uas xav tau cov khoom siv hluav taws xob ruaj khov thiab tsis tu ncua nrog cov npoo rau kev loj hlob, xws li lub Hoobkas nrog cov tshuab hnyav, lub khw nrog HVAC systems lossis ib cheeb tsam fais fab substation pub rau ntau lub tsev.
Customization thiab Standards
Cov kev xaiv kho kom haum muaj xws li qhov sib txawv ntawm qhov sib txawv voltage thiab kais hloov pauv (tawm- Circuit Court lossis ntawm -load), cov roj insulating tshwj xeeb rau huab cua huab cua, sib txawv ntawm qhov sib txawv thiab kev tiv thaiv qib, tooj liab lossis aluminium windings, thiab pawg vector kom phim lub network hauv zos. Txhua chav nyob yog tsim thiab sim rau IEC 60076, ANSI C57 thiab cov qauv GB uas cuam tshuam; cov ntawv xeem thiab cov ntawv pov thawj xeem muab cov pov thawj xav tau rau qhov kev lees paub thiab kev sib txuas ntawm kab sib chaws.
Installation thiab ua hauj lwm Notes
Lub transformer yuav tsum tau nruab rau ntawm lub hauv paus theem uas muaj peev xwm tshem tawm kom txias thiab txij nkawm, tiv thaiv los ntawm dej nyab thiab nrog cov roj ntim tau txiav txim siab qhov twg hauv zos cov cai yuav tsum tau ua. Thaum lub sijhawm ua haujlwm, saib xyuas cov roj kub: qhov siab tshaj - roj kub siab tshaj li 95℃qhia tias muaj teeb meem overload lossis txias. Rau kev teeb tsa saum toj 1,000 m altitude, derate lub chaw thau khoom raws li IEC 60076-2 kev taw qhia.
FAQ
Dab tsi yog tag nrho -load tam sim no ntawm 630 kVA transformer ntawm 0.4 kV?
Rau peb -theem 630 kVA transformer nrog 0.4 kV theem nrab, tag nrho -load kab tam sim no yog kwv yees li 630,000 / (1.732 x 400)=909 A. Ntawm 10 kV thawj, qhov tam sim no yog kwv yees li 36 A.
Cov roj 630 kVA puas tuaj yeem siv tau rau hauv tsev?
Yog lawm, muab qhov kev teeb tsa ua raws li cov kev cai tiv thaiv hluav taws rau cov roj- cov khoom siv puv, piv txwv li thaj chaw thiab hluav taws kub - ntsuas kev sib cais. Ntau tus neeg yuav khoom xav kom qhuav -hom tsev nyob hauv tsev; ib qho roj- puv chav nyob sab hauv tsev feem ntau yuav tsum muaj kev tiv thaiv ntxiv thiab ntsuas cua.
Dab tsi yog qhov txawv ntawm cov roj ntxhia thiab ester roj hauv 630 kVA transformer?
Cov roj ntxhia yog tus qauv, tus nqi - ua haujlwm zoo insulating kua nrog zoo - tsim cov txheej txheem xeem. Ester roj (natural lossis hluavtaws) muaj qhov hluav taws kub siab dua, yog biodegradable thiab nqus dej noo zoo dua, uas haum rau qhov chaw rhiab heev, tab sis lawv raug nqi ntau dua thiab xav tau kev sib txawv thaum lub sijhawm ua haujlwm.
Kuv yuav txiav txim siab li cas cov chav kawm poob rau 630 kVA transformer?
Tshawb xyuas cov kev cai ntawm kev siv hluav taws xob ntawm lub khw muag khoom. Hauv Suav teb, GB 20052-2024 txhais cov kev txwv tsis pub thauj khoom thiab thauj khoom poob rau txhua qib; Hauv Tebchaws Europe, txoj cai Ecodesign txhais Tier 1 thiab Tier 2 qib. Xaiv cov qib raws li qhov yuav tsum tau ua ntawm kev sib tw thiab kev suav nqi ntawm lub neej.
Yuav ua li cas tu ib tug 630 kVA roj- puv transformer xav tau?
Kev kuaj pom txhua xyoo, roj qib thiab ntsuas kub, thiab kuaj roj txhua txhua 1-2 xyoos rau lub zog dielectric, noo noo thiab acidity. Tom qab ib qho kev ua txhaum lossis kev ua haujlwm relay, ua cov tshuaj yaj yeeb yaj kiab thiab, yog tias xav tau, kev ntsuas hluav taws xob xws li kev hloov pauv, kev tiv thaiv kev tiv thaiv thiab winding tsis kam.
Lub 630 kVA transformer siv sijhawm ntev npaum li cas los tsim khoom?
Lub sij hawm txhuas lub sij hawm yog 20-40 hnub ua hauj lwm rau tus qauv tsim, nyob ntawm qhov voltage piv, poob chav kawm, accessories thiab txiav txim kom muaj nuj nqis. Customized lossis hom-tested designs tuaj yeem siv sijhawm ntev dua, yog li lub sijhawm xa khoom yuav tsum tau lees paub ntawm theem kev txiav txim.