Cov160 kVA Qhuav-Hom Transformeryog lub hauv paus nruab nrab- muaj peev xwm siv hluav taws xob rau cov chaw ua lag luam, chaw ua lag luam thiab nruab nrab- kev cob qhia, thiab kev tshawb fawb, kev saib xyuas tsis tu ncua yog tus yuam sij rau ncua nws lub neej kev pab cuam (txog 25 xyoos), zam kev tsis raug xav txog thiab tswj xyuas lub zog kom zoo.

 

Zoo li GNEE's 100 kVA Qhuav-Hom Transformer (ncauj lus kom ntxaws hauv 100kva-peb-theem- qhuav- hom-transformer- xaiv), tus qauv 160 kVA tau txais txiaj ntsig zoo ntawm cov roj- qauv tsim dawb, kev saib xyuas yooj yim thiab poob qis- cov kev ua tau zoo no ua kom yooj yim txij nkawm txhua hnub thaum xav tau lub hom phiaj rau nws qhov siab - overload thiab loj - cov yam ntxwv muaj peev xwm.

 

Cov lus qhia no qhia txog cov lus qhia tseem ceeb ntawm kev saib xyuas kom ntev - lub sijhawm ua haujlwm, sib koom ua ke cov khoom lag luam zoo, thiab cov ntaub ntawv saib xyuas kev sib koom ua ke nrog 100 kVA series, muab kev cob qhia kev tshaj lij rau pab pawg thiab cov neeg ua haujlwm tu.

 

Cov Tswv Yim Kho Txhua Hnub (Kev Tshuaj Xyuas Txhua Hnub, 10-15 feeb / Lub Limtiam)

 

Kev saib xyuas txhua hnub tsom rau kev kuaj xyuas yooj yim, nrawm, siv lub zog ntawm 160 kVA tus qauv qis- kev tu kom zoo (tsis muaj roj hloov, tsis muaj roj qib tshuaj ntsuam xyuas- ib yam li 100 kVA series) kom tsis txhob muaj teeb meem me me nce ntxiv:

 

  • Ntxuav tu: Siv cov txhuam mos qhuav los yog qis dua - compressed cua kom tshem tawm cov plua plav tawm ntawm qhov chaw hloov pauv, cov cua kub dissipation vents thiab windings - cov plua plav paug yuav txo tau cov cua sov dissipation efficiency, tshwj xeeb tshaj yog qhov tseem ceeb rau 160 kVA qauv siab -load hauj lwm (tsis zoo li 100 kVA series), nws yog ib qho tseem ceeb ntawm kev tu vaj tse.
  • Kev Ua Haujlwm Saib Xyuas Kev Ua Haujlwm: Mloog rau kev khiav hauj lwm suab nrov (tsawg dua los yog sib npaug li 55dB hauv AN hom)- buzzing txawv txav los yog crackling qhia tias xoob windings los yog core faults; txheeb xyuas qhov kub thiab txias ntawm tes (tsis muaj qhov pom tseeb tshaj qhov cua sov, Tsawg dua lossis sib npaug li 40℃saum toj ib puag ncig), tau txais 100 kVA series 'suab nrov thiab ntsuas kub ntsuas.
  • Terminal & Wiring Check: Visually soj ntsuam high/low-voltage wiring terminals for looseness, discoloration or oxidation-tighten loose terminals with a torque wrench (raws li GNEE's specification), tib yam li 100 kVA series 'terminal tu lub tswv yim hauv 100kva-peb-theem- qhuav-hom-transformer- xaiv.

 

Tsis tu ncua Kev tsom xam (Lub hli / Peb Hlis / Ib Hlis, Lub Hom Phiaj rau 160 kVA yam ntxwv)

 

Kev saib xyuas tsis tu ncua tsom rau cov khoom tseem ceeb, sib txuas nrog 100 kVA series 'kev saib xyuas kom pom tseeb (kev rwb thaiv tsev, hauv av) nrog rau 160 kVA qauv cov kev xav tau tshwj xeeb (overload, txias system):

 

Kev Kho Ib Hlis (30 feeb / hli)

  • Tshawb xyuas lub tshuab ua kom txias: Rau AN hom, tshawb xyuas qhov cua nkag rau kev thaiv; rau AF hom (customizable), ntsuas cua txias kiv cua rau ib txwm ua haujlwm- tseem ceeb rau 160 kVA qauv siab - muaj peev xwm dhau (tsis zoo li 100 kVA series, nws feem ntau ua haujlwm ntawm cov khoom hnyav dua).

 

  • Txheeb xyuas qhov kev sib txuas hauv av: Tshawb xyuas ob qhov kev sib txuas hauv av rau kev xeb lossis xoob, xyuas kom cov av tiv thaiv tsawg dua lossis sib npaug ntawm 4Ω-tib yam li 100 kVA series 'kev saib xyuas hauv av hauv 100kva-peb-theem- qhuav- hom-transformer{100}{101}

 

Kev Kho Lub Plaub Hlis (1 Teev / Peb Hlis)

  • Rwb thaiv tsev Performance Check: Siv lub megohmmeter los ntsuam xyuas cov rwb thaiv tsev rwb thaiv tsev (Ntau dua lossis sib npaug ntawm 100MΩ ntawm 25 degree)- 160 kVA qauv F / H chav kawm rwb thaiv tsev (tib yam li 100 kVA series) ua kom muaj zog rwb thaiv tsev, tab sis kev kuaj xyuas tsis tu ncua.

 

  • Overload Protection Check: Kuaj overcurrent, tshaj -kub tiv thaiv cov cuab yeej kom ntseeg tau tias lawv ua rau lub tswb thiab hluav taws xob txiav kom raug-ua raws li 160 kVA qauv qhov kev ua kom muaj peev xwm ua tau zoo tshaj (120% rau 3h), nruj dua li 100 kVA series 'overload tiv thaiv check.

 

Kev Kho Txhua Xyoo (2 Teev / Xyoo)

  • Comprehensive Core & Winding Inspection: Qhib lub hau kev tiv thaiv los xyuas seb qhov cua deformation, core loosening lossis rwb thaiv tsev yellowing - kho lossis hloov qhov puas nrog GNEE cov khoom siv raws li tus qauv.

 

  • Tag Nrho Cov Txheej Txheem Calibration: Calibrate kub sensors, voltage / tam sim no meters, thiab kho cov kais dej yog tias xav tau; ntxuav lub transformer sab hauv kom huv si, inheriting 100 kVA series 'txhua xyoo kev tu txhua xyoo.

 

  • Kev Ntsuas Kev Ua Haujlwm: Tshawb xyuas tsis muaj-load poob (tsawg dua lossis sib npaug li 320W) thiab tag nrho -load efficiency (Ntau dua lossis sib npaug li 98.7%)- xyuas kom tus qauv 160 kVA tswj nws qhov qis- poob kom zoo dua, tib yam li 100 kVA series 'kev ua haujlwm tau zoo nyob rau hauv 100kva-peb-theem- qhuav- hom-transformer- xaiv.

 

Fault Prevention & Emergency Maintenance Tips

 

Muab cov 160 kVA qauv cov khoom zoo nrog cov tswv yim ntsuas thaum muaj xwm ceev, xa mus rau 100 kVA series 'kev ua txhaum kev ua haujlwm:

  • Overload Fault Prevention: Zam kev ua haujlwm ntev - lub sijhawm ua haujlwm dhau 120% rated load; yog tias overload tshwm sim, txo cov load tam sim ntawd thiab cia lub transformer txias cia- nws muaj peev xwm overloaded (ib tug tseem ceeb kom zoo dua) tso cai luv luv - lub sij hawm peaks tab sis yuav tsum tau kev pab raws sij hawm.
  • Rwb thaiv tsev laus tiv thaiv: Khaws qhov chaw teeb tsa kom qhuav (cov av noo tsawg dua lossis sib npaug li 75%); zam corrosive gas los yog plua plav hnyav-leveraging nws kaw rwb thaiv tsev tsim (kuj los ntawm 100 kVA series) kom ntev rwb thaiv tsev lub neej.
  • Kev tuav xwm txheej ceev: Yog hais tias muaj suab nrov txawv txav, overheating los yog rwb thaiv tsev tawg, txiav tawm tam sim ntawd; hu rau GNEE pab pawg kws tshaj lij (24/7 kev txhawb nqa)- qauv 160 kVA tus qauv tsim (tib yam li 100 kVA series) ua kom muaj kev kuaj xyuas thiab kho sai.

 

GNEE 160 kVA Qhuav-Type Transformer Maintenance-Related Technical Parameters

Lub npe Parameter Kev saib xyuas-Qhov Kev Qhia Kom Zoo
Rated Peev Xwm 160kVA ua
Rwb thaiv tsev Class F Class (upgradeable rau H Class)
Txoj kev txias AN (Air Natural) / AF (Air Forced)
Tsis muaj -Load Poob Tsawg dua lossis sib npaug rau 320W (tsawg- poob)
Tshaj peev xwm 120% rau 3h; 150% rau 20 min
Qib tiv thaiv IP30 / IP40 / IP54 yeem
Ua haujlwm nrov nrov Tsawg dua lossis sib npaug rau 55dB (AN hom)
Accessory Standardization Tus txheej txheem tag nrho

 

Xaus

Lub 160 kVA Qhuav-Type Transformer ntev- lub sijhawm ua haujlwm nyab xeeb thiab ruaj khov yog nyob ntawm kev tshawb fawb, kev saib xyuas tsis tu ncua-leveraging nws cov txiaj ntsig tseem ceeb ntawm cov roj-dawb tsim, yooj yim txij nkawm, tsis tshua muaj kev poob thiab txhim kho lub peev xwm ntau dhau (tau txais los ntawm GNEE's 100 kVA series 100kva-peb-theem- qhuav-hom-transformer- xaiv). Los ntawm kev ua raws li ua ntej- npaj kev tu, kev kuaj xyuas txhua hnub, kev saib xyuas tsis tu ncua thiab kev tiv thaiv kev ua txhaum, koj tuaj yeem txuas nws lub neej kev pab cuam, tswj kev ua haujlwm kom zoo thiab zam lub sijhawm poob qis.

Tau txais ib nqe lus

 

GNEE's 160 kVA Dry-Type Transformer inherits 100 kVA series' yooj yim- tu thiab qis- tsis zoo, nrog rau kev ua kom zoo ntxiv rau nws qhov nruab nrab - cov yam ntxwv muaj peev xwm. Peb pab pawg kws tshaj lij muab kev cob qhia kev saib xyuas dawb, 24/7 online kev taw qhia thiab cov khoom siv tau zoo (tshaj nrog 100 kVA series) kom yooj yim txij nkawm ua haujlwm.

 

Yog tias koj xav tau kev taw qhia kev saib xyuas rau koj 160 kVA Qhuav -Hom Transformer lossis xav paub ntau ntxiv txog nws qhov qis -kev tu kom zoo,hu rau GNEE tam sim ntawd kom tau txais kev txhawb nqa kev tshaj lij thiab cov khoom lag luam!

Xa kev nug